Omnistab PC DT01
· Chemical Name:Unpublished
· CAS:Unpublished
· Chemical Name:Unpublished
· CAS:Unpublished
OMNISTAB® PC-DT01 can be used for the production of medical consumables such as dialysis machine, blood collection devices, high-pressure injectors, surgical masks, etc.. Due to the strong radiation energy, normal PC materials are easy to yellow, fade, degrade, and reduce performance when subjected to irradiation sterilization. After being stored for a period of time after irradiation, more severe degradation may occur on normal PC materials. OMNISTAB® PC-DT01 has little change in yellow index after irradiation and can highly keep mechanical properties.
Radiation dose | Test item | Unit | Normal Pc | PC-DTO1 |
- | Melt index | g/10min | 10.0 | 12.0 |
0 kGy | Transmittance | % | 85.3 | 86.8 |
Haze | % | 4.6 | 3.7 | |
Yellowness index | - | 3.8 | -5.1 | |
25 kGy | Transmittance | % | 79.7 | 77.3 |
Haze | % | 4.8 | 3 | |
Yellowness index | - | 23.8 | 3 2 | |
Value added of YI | - | 20 | 8.3 | |
50 kGy | Transmittance | % | 70.4 | 73.2 |
Haze | % | 3.4 | 3.2 | |
Yellowness index | - | 45.2 | 9.1 | |
Value added of YI | - | 41.4 | 14.2 |
If you have questions, please fill out the form below and we will contact you as soon as possible
For better service and technical solution,please fill in the below form.
All information will be keep confidential.